> Products > FLEXIBLE CORD > 60227 KS IEC 43


  300/300V Cord for indoor decorative lighting chains
Application This wire is for vinyl insulated flexible cords under 300/300V.
Construction Conductor : Flexible Stranded Annealed Copper (Class 5)
Insulation : PVC/D COMPOUND (Dual Extrusion)
Color Colors Requested
Temperature Rating 70 ℃
Standard KS C IEC 60227-5
Marking ㉿ KS C IEC 60227-5 300/300V 60227 KS IEC 43 00mm² KISEONG 0000 RoHS


Conductor Thickness of
each layers of
insulation
Minimum value
Overall insulation
thickness
Minimum value
Overall insulation
thickness
Mean value
Mean overall diameter Max. Conductor
Resistance 20℃
Minimum
insulation
resistance
at 70℃
Approx.
Weight
Packing
Length
Nominal cross
-sectional
area
Maximum
Diameter
of wire
Approx.
Diameter
Lower limit Upper limit Copper Tinned
mm² mm mm mm mm mm mm mm Ω/km Ω/km MΩ/km kg/km m
0.5 0.21 0.9 0.2 0.6 0.7 2.3 2.7 39.0 40.1 0.014 10 500
0.75 0.21 1.1 0.2 0.6 0.7 2.4 2.9 26.0 26.7 0.012 13 500